| Conductors: |
fine stranded wires of bare copper |
CEI EN 60228 (Tab. 9) rule |
| Flame protection: |
by mica-glass tape (thickness > 0,10 mm) |
|
| Insulation: |
thermoplastic rubber |
CEI 20-11 - CEI EN 50363 |
| Cores colour code: |
|
CEI UNEL 00722 - HD 308 |
| Flame protection: |
by glass fibre tape |
|
| Outer sheath: |
polymer compound |
CEI 20-11 - CEI EN 50363 |
| Outer sheath colour: |
orange RAL 2004 |
|
| Fire retardant: |
|
CEI EN 50266-2-4 cat. C |
| Flame retardant: |
|
CEI EN 60332-1-2 |
| Halogen free: |
<0,5 mg/g - 0,5% |
CEI EN 50267-2-1/2 - IEC 60754-1/2 |
| Toxicity of gases: |
toxicity index < 2% |
CEI 20-37/4-0 |
| Smoke emission: |
> 60% |
CEI EN 61034-2 |
| Fire resistant test: |
during 90 min. at 830 °C -0 ÷+40 °C |
CEI EN 50200 for Ø ≤ 20 mm |
| Fire resistant test: |
during 120 min. at 830 °C -0 ÷ +40 °C |
CEI EN 50362 for Ø > 20 mm |
| Fire resistant test: |
during 180 min at 750 °C (FE 180) |
IEC 60331-21 - VDE 472-814 |
| Fire resistant test: |
E30 |
DIN VDE 4102-12 |
| Electric resistant: |
according to |
CEI EN 60228 (Tab. 9) rule |
| Current capacities: |
|
CEI UNEL 35024/1 - CEI UNEL 35026 |
| Working voltage: |
0,6/1 kv |
|
| Max voltage: |
1,2 kV |
|
| Testing voltage: |
4 kV |
|
| Max operating temperature: |
90° C |
|
| Short-circuit temperature: |
250 °C |
|
| Min temperature: |
0 °C |
|
| Outer printing: |
BERICA CAVI S.P.A. (VI) (N)HXH FE180/E30 IEC 60331-21 DIN VDE 4102-12 CE YEAR OF MANUFACTORING/LOT - Nr. OF CORES x/G CROSS SECTION PROGR. METRIC |
|
| Bending radius: |
Ø x 14 |
|